Temperature monitoring
TempOne
Monitor the temperature of connections, cable terminations, and busbars to identify hot spots and degradation trends. TempOne offers 24 temperature channels per module, plus an ambient reference, accessible via web browser and integrating with SCADA systems via Modbus.
Modular system for continuous temperature monitoring in electrical connections.






Key differentiators
Designed for the air gap, not adapted to it.
Monitoramento térmico para antecipar falhas em conexões elétricas
24 channels per module
Monitor up to 24 temperature points per module, plus a dedicated channel for ambient reference.
Access via browser
Access the data on the embedded web platform, without local installation and with a lifetime usage license.
Identificação de pontos quentes
Monitor temperatures to identify abnormal warming, imbalances between phases, and degradation trends.
Integration with SCADA systems
Integrate monitoring with plant supervision via Modbus TCP or RS-485.
Aplicação em diferentes conexões
Monitor medium voltage cable terminations, splices, busbars, and connections in electrical switchboards and panels.
Complete modular system
Module with DIN rail mounting, epoxy-encapsulated sensors, PTFE cables, and proprietary software.


Overview and application
Product: TempOne — Modular temperature monitoring system. Application described in the datasheet: medium voltage cable terminations in GIS panels. Channels: 24 temperature channels per unit, always fully equipped. Measurement: absolute temperature per cable, without current measurement. Architecture: modular and scalable, with up to 7 bays or compartments per unit. Multiple units can be interconnected, with centralized data aggregation. Purpose: to identify thermal imbalances, hot spots, and incipient contact failures. Design lifespan: 10 years. Calibration: no field calibration required; sensors characterized at the factory.
Measurement and precision
Measurement range: 0 to 130 °C. Accuracy between 40 and 105 °C: ±0.3 °C in the worst case, without individual calibration and with interchangeable sensors. Accuracy between 0 and 130 °C: ±1.3 °C in the worst case, without individual calibration and with interchangeable sensors. Resolution: less than 0.001 °C, with a 24-bit analog-to-digital converter. Acquisition method: ratiometric measurement. Note: resolution and accuracy are distinct characteristics.
Sensors and cabling
Sensors: passive, 2-wire, without powered electronics at the high-voltage termination. Cable: twisted pair with PTFE insulation. Conductor: copper, 0.75 mm², with resistance ≤ 26 Ω/km. Nominal cable voltage: 600 V. Nominal cable temperature: −60 to +200 °C. This range refers to the cable; the system measurement range is 0 to 130 °C. Standard length: 3.5 m per sensor. Extension: up to 15 m, with cable error ≤ 0.08 °C over 15 m. Connection: 2 wires, no Kelvin or 4-wire connection required. Installation: surface of medium-voltage cable termination, elbow type, subject to heat and high electromagnetic interference.
Electronics and protections
Controller: dual-core microcontroller. Analog-to-digital converter: 24-bit, ratiometric. Galvanic isolation: between the analog domain of the sensors and the logic domain, with SPI digital isolators and isolated DC/DC converter. Input protection against electrostatic discharge: IEC 61000-4-2, ±20 kV per contact. Input protection against fast electrical transients: IEC 61000-4-4, 40 A, as indicated in the datasheet. Input protection against surges: IEC 61000-4-5, 4 A, 8/20 µs waveform. The references describe the protections indicated in the datasheet, not certifications of the complete product.
Power supply
Input voltage: 24 VDC nominal. Power: 10 W. DC/DC converter: pre-certified, with 1600 VDC isolation. Protections: input undervoltage, overcurrent and output short circuit. Electromagnetic compatibility of the DC/DC converter: EN 55032 Class A and IEC 61000-4-2, -3, -4, -5 and -6. Pre-certification of the converter does not represent certification of the complete product.
Communication and integration
Ethernet: 10/100, Modbus TCP and embedded web server. Serial interface: isolated RS-485, with Modbus RTU. Integration: SCADA systems via Modbus TCP or RTU. RS-485 transceiver: ISO1500, galvanically isolated. Transceiver isolation: 3 kV RMS, compliant with UL 1577. Bus protection: ±8 kV IEC ESD on pins. Receiver with safe state in open circuit, short circuit or idle bus. Thermal shutdown protection.
History, trends and alerts
Local recording: microSD card, with dated historical records. Clock: embedded RTC, with CR2032 backup battery. Monitoring: real-time temperature, trends, and minimum, maximum, and average values per channel. Configurable alarms: over-temperature, temperature difference between phases, and difference relative to the reference channel. Limits per group: warning and critical over-temperature, rise above ambient temperature, and phase difference in three-phase cable groups. Email notifications: via SMTP, for over-temperature events, phase difference, and difference relative to the environment. Recipients: severity filter per recipient and test email sending function.
Web platform
Access: interface served directly by each TempOne unit, accessible via browser, without software installation. The datasheet states that no licenses are required. Dashboard: channel count in normal, warning, and critical states. Termination cards: current temperature, elevation above ambient temperature, and alarm status. Monitor: selectable channel graphs in an adjustable time window. Statistics: range, minimum, maximum, and average, with real-time alarm indication. Navigation: selecting a channel on the dashboard opens its analysis in the Monitor. Configuration: activation, identification, and assignment to groups of the 24 channels and the reference. Validation: changes verified before being applied to the device. Alarms: configuration of limits per group and email notifications.
Display and indicators
Display: 0.91-inch monochrome OLED. Keys: 3 navigation keys. Status LEDs: Power, CPU-OK, Activity, Connected, Failure, Alarm, Ethernet, Modbus TCP, RS-485, Web server, and Wi-Fi. Note: the presence of the Wi-Fi indicator does not confirm a wireless communication interface, as it is not specified in the communications section of the datasheet.
Mechanical characteristics and environment
Mounting: DIN rail. Enclosure: ABS/PC. Approximate dimensions: 88 × 158 × 59 mm. Field connections: integrated terminals for 24 sensor channels, 24 VDC power supply and RS-485. Environment: design described for harsh electrical environments, electromagnetic immunity and high availability. Do not add IP protection rating, certifications or operating temperature of the module, as this data is not provided.
Supplies and accessories
TempOne unit: fully equipped 24-channel module in a DIN rail enclosure, powered by 24 VDC. Sensors included: 24 temperature sensors, each with a 3.5 m cable. Optional accessory: 50 m cable roll for sensor extension. Optional accessory: pack of 10 connectors for sensor cable extension. Specification source: TempOne Technical Datasheet, AQTech Power Prognostics, Rev. 0.1. Specifications derived from engineering design records, subject to change without notice. Accuracy, range, and nominal characteristics reflect design parameters and do not constitute a guarantee of performance for a specific application.
TempOne Software
What temperature reveals about your electrical connections.
Identify hot spots, phase imbalances, and degradation trends before a thermal failure. TempOne continuously monitors connection temperatures and an ambient reference to support predictive maintenance.
Integrated monitoring of operations
Access the data through the embedded web platform, without local installation and with a lifetime usage license. Modbus integration allows monitoring of temperatures in the plant's SCADA system.
Connection temperature
Continuous monitoring of cable terminations, joints, busbars, and other electrical connection points.
Environmental reference
Dedicated measurement of ambient temperature to contextualize the heating of the connections.
Identifying hotspots
Monitoring for abnormal heating, which may indicate increased contact resistance.
Imbalances between phases
Comparison of temperatures to identify thermal differences between phases.
Degradation trends
Monitoring thermal evolution to support maintenance planning before a failure.
INTEGRATION WITH THE PLANT
Connect thermal monitoring to your operation.
TempOne integrates with the plant's SCADA system via Modbus TCP and RS-485. Its embedded web platform allows data to be accessed through a browser, without local installation, and with a lifetime usage license.
Integration with SCADA systems via Modbus
Continuous monitoring of electrical connections and terminations.
Temperature data to support predictive maintenance
From connection to the monitoring system
With 24 temperature channels and an ambient reference per module, TempOne tracks different electrical connection points and makes the data available for consultation on the web platform or the plant's SCADA system.
LEARN MORE, LEARN BEFOREHAND
Speak to an air gap monitoring specialist.
Send us the machine data — nominal air gap, number of poles, and installation access — and we will indicate the range, the number of probes, and the installation approach.
Florianópolis, Brazil · Porto, Portugal · Winter Garden, FL