Key differentiators
Designed for the air gap, not adapted to it.
Sonda plana de baixo perfil
Instalação no fundo do entreferro ou na borda, no estator ou no rotor.
Imune ao ambiente da máquina
Compensado por temperatura e não afetado por campos magnéticos intensos, vibrações e depósitos.
Medição capacitiva sem contato
Princípio capacitivo de alta precisão, com alta repetibilidade e baixo ruído de saída.
IP67 sealed electronics
Invólucro projetado para ambientes severos de campo, com saída de corrente opto-isolada.
Sonda em compósito carbono-FR4
Alta estabilidade construtiva para longa permanência dentro da máquina.
Factory calibrated assembly
Paired probe and conditioner, with individual test and calibration report (MTR).
Model

Measures
Principle
Air gap, 3…50 mm (three ranges)
Non-contact capacitive
Bandwidth
Probe thickness
Probe temperature
DC…1 kHz (−3 dB)
2…3 mm
-20…140 °C
Output
Magnetic environment
Delivery
4…20 mA / 2…10 V, isolated
Magnetic field: immunity
Factory-calibrated matched set,
individual MTR
GapOne Software
What the air gap reveals before vibration.
Identifies the risk of rotor-stator contact before it becomes a fault. Displays minimum, maximum, and average clearance, circumferential profile, and long-term drift—supporting commissioning, maintenance shutdowns, start-up, shutdown, and comparisons with and without load.
Integrated diagnostics on the AQTech platform.
Air gap data can be analyzed along with vibration, partial discharges, load, excitation current, and angular reference—and with the pole-to-pole magnetic signature of FluxOne—to confirm the origin of the fault.
Slack profile
Minimum, maximum, and average air gap throughout the circumference.
Rotor and stator geometry
Evaluation of circularity, concentricity, and ovality.
Eccentricity analysis
Separation between static and dynamic eccentricity, with angular reference.
Comparison of operating conditions
Evaluation during startup, shutdown, load variations, and thermal transients.
Trends and warnings
Monitoring of long-term drift and configurable minimum clearance and circularity limits.
OPEN ARCHITECTURE
It integrates with what your plant already uses.
Integration with existing SCADA, DCS, and asset management systems, using standard and documented industrial protocols — no proprietary format. The asset owner retains full ownership of their data, independent of any machine supplier.
Open data through standard industry protocols.
Eccentricity confirmation by geometry-independent measurement.
Applicable to commissioning, refurbishments, and ongoing monitoring.
It combines with FluxOne.
FluxOne measures magnetic flux pole-to-pole and identifies weak poles. In conjunction with GapOne, it distinguishes winding faults from eccentricity effects.
LEARN MORE, LEARN BEFOREHAND
Speak to an air gap monitoring specialist.
Send us the machine data — nominal air gap, number of poles, and installation access — and we will indicate the range, the number of probes, and the installation approach.