Air gap monitoring

GapOne

Non-contact measurement of rotor-stator clearance in hydraulic generators and large rotating machinery — temperature compensated, immune to strong magnetic fields, and delivered as a factory-calibrated assembly.

Low-profile capacitive air gap sensor for rotating machinery.

air_gap_software_notebook.png
image (7).png
certifications-11.png
certifications-12.png
certifications-14.png
certifications-13.png
certifications-15.png

Key differentiators

Designed for the air gap, not adapted to it.

Sonda plana de baixo perfil

Instalação no fundo do entreferro ou na borda, no estator ou no rotor.

Imune ao ambiente da máquina

Compensado por temperatura e não afetado por campos magnéticos intensos, vibrações e depósitos.

Medição capacitiva sem contato

Princípio capacitivo de alta precisão, com alta repetibilidade e baixo ruído de saída.

IP67 sealed electronics

Invólucro projetado para ambientes severos de campo, com saída de corrente opto-isolada.

Sonda em compósito carbono-FR4

Alta estabilidade construtiva para longa permanência dentro da máquina.

Factory calibrated assembly

Paired probe and conditioner, with individual test and calibration report (MTR).

Model

Measures

Principle

Air gap, 3…50 mm (three ranges)

Non-contact capacitive

Bandwidth

Probe thickness

Probe temperature

DC…1 kHz (−3 dB)

2…3 mm

-20…140 °C

Output

Magnetic environment

Delivery

4…20 mA / 2…10 V, isolated

Magnetic field: immunity

Factory-calibrated matched set,
individual MTR

GapOne Software

What the air gap reveals before vibration.

Identifies the risk of rotor-stator contact before it becomes a fault. Displays minimum, maximum, and average clearance, circumferential profile, and long-term drift—supporting commissioning, maintenance shutdowns, start-up, shutdown, and comparisons with and without load.

Integrated diagnostics on the AQTech platform.

Air gap data can be analyzed along with vibration, partial discharges, load, excitation current, and angular reference—and with the pole-to-pole magnetic signature of FluxOne—to confirm the origin of the fault.

Slack profile

Minimum, maximum, and average air gap throughout the circumference.

Rotor and stator geometry

Evaluation of circularity, concentricity, and ovality.

Eccentricity analysis

Separation between static and dynamic eccentricity, with angular reference.

Comparison of operating conditions

Evaluation during startup, shutdown, load variations, and thermal transients.

Trends and warnings

Monitoring of long-term drift and configurable minimum clearance and circularity limits.

OPEN ARCHITECTURE

It integrates with what your plant already uses.

Integration with existing SCADA, DCS, and asset management systems, using standard and documented industrial protocols — no proprietary format. The asset owner retains full ownership of their data, independent of any machine supplier.

  • Open data through standard industry protocols.

  • Eccentricity confirmation by geometry-independent measurement.

  • Applicable to commissioning, refurbishments, and ongoing monitoring.

It combines with FluxOne.

FluxOne measures magnetic flux pole-to-pole and identifies weak poles. In conjunction with GapOne, it distinguishes winding faults from eccentricity effects.

LEARN MORE, LEARN BEFOREHAND

Speak to an air gap monitoring specialist.

Send us the machine data — nominal air gap, number of poles, and installation access — and we will indicate the range, the number of probes, and the installation approach.

Florianópolis, Brazil · Porto, Portugal · Winter Garden, FL

AQTech Brazil

Rod. José Carlos Daux 8600, Florianópolis - SC, 88050-000, Brazil

AQTech United States

5370, Bowman Drive - Winter Garden, FL - 34787, USA | Phone: +1 (321) 318 1294

AQTech Europe

R. Pintor César Abbot 50, 4150-206 - Porto, Portugal | Phone: +351 911996958

ISO-9001_45001.png

All rights reserved.

Privice Policy.

© 2024 AQTech.

bottom of page